Cause of defect
|
Way of elimination
|
One of lamps of external illumination does not burn
|
|
The lamp has fused
|
To replace a lamp
|
Malfunction of a cartridge of a lamp, conducting, infringement of connection with "weight"
|
To eliminate malfunction
|
Lamps of headlights do not burn
|
|
Have fused lamps
|
To replace lamps
|
Has fused a safety lock №26 or №28 (on 10)
|
To check up absence of short circuit and to replace a safety lock
|
Malfunction of the switch of illumination
|
To check up the switch
|
Malfunction of conducting or connection with "weight"
|
To eliminate malfunction
|
Lamps of back dimensional light and illumination lantern do not burn
Licence plate
|
|
Has fused a safety lock №2 or №6 (on 10)
|
To check up absence of short circuit and to replace a safety lock
|
The fusible insert of the storage battery (on 50) has fused
|
To replace a fusible insert
|
Malfunction of the relay of back lanterns
|
To check up the relay
|
Malfunction of the switch of external illumination
|
To check up the switch
|
Malfunction of conducting or infringement of connection with "weight"
|
To eliminate malfunction
|
Lamps of a signal of braking do not burn
|
|
Has fused a safety lock №19
(On 15)
|
To replace a safety lock and to check up absence of short circuit
|
Malfunction of the switch of a signal of braking
|
To adjust or replace the switch
|
Malfunction of conducting or connection with "weight"
|
To eliminate malfunction
|
Lamps of a signal of braking do not die away
|
|
Malfunction of the switch of a signal of braking
|
To adjust or replace the switch
|
Lamps of a suspension bracket of the panel of devices do not burn
(Dimensional light burns)
|
|
Malfunction of brightness control of illumination of devices
|
To check up a regulator
|
Malfunction of conducting or connection with "weight"
|
To eliminate malfunction
|
The turn index on the one hand does not work
|
|
The lamp has fused
|
To replace a lamp
|
Malfunction of the switch of indexes of turn
|
To check up the switch
|
Malfunction of conducting or infringement of connection with "weight"
|
To eliminate malfunction
|
Turn indexes do not work
|
|
Has fused a safety lock №5
(On 10)
|
To replace a safety lock and to check up absence of short circuit
|
Malfunction of the relay-breaker
|
To check up the relay-breaker
|
Malfunction of the switch of indexes of turn
|
To check up the switch
|
Malfunction of conducting or infringement of connection with "weight"
|
To eliminate malfunction
|
The alarm system does not work
|
|
Has fused a safety lock №20 (on 15)
|
To replace a safety lock and to check up absence of short circuit
|
Malfunction of the relay-breaker
|
To check up the relay-breaker
|
Malfunction of the switch of the alarm system
|
To check up the switch
|
Malfunction of the relay of the alarm system
|
To replace the relay
|
Malfunction of conducting or infringement of connection with "weight"
|
To eliminate malfunction
|
The raised or lowered frequency of a blinking of indexes of turn
|
|
Capacity of lamps of indexes more low or above norm
|
To replace lamps
|
Malfunction of the relay-breaker
|
To check up the relay-breaker
|
Backing light does not join
|
|
Has fused a safety lock №5
(On 10)
|
To replace a safety lock and to check up absence of short circuit
|
Malfunction of the switch of light of a backing
|
To check up the switch
|
Lamps of the console of a roof in salon do not burn
|
|
Has fused a safety lock №29
(On 15)
|
To replace a safety lock and to check up absence of short circuit
|
Malfunction of conducting or infringement of connection with "weight"
|
To eliminate malfunction
|